Kit de lima endodoncia InnoTaper movimiento continuo
“Progressive control in continuous rotation”
Variable taper: InnoTaper includes a series of “forming” and “finishing” files, all designed with variable taper, bringing greater cutting efficiency and ensuring smoother instrument transitions.
Optimized Design: The optimized cross-sectional design significantly increases the debris capacity. Combined with a step-through design, it provides more efficient debris removal, ensuring a smooth and effective cutting process.
Improved Durability: InnoTaper uses advanced heat treatment technology, offering exceptional flexibility and improved fatigue resistance, ensuring efficient and long-lasting performance.
Safe Guide Tip: InnoTaper’s safe guide tip offers exceptional centering ability, reducing the risk of deflection and lateral perforation, improving safety during preparation.
Features:
- KP-E0-19
- Diameter: 0.19 mm
- Taper (%): 04vt
- Cross section: Convex-sided triangle
- Stem Color: –
- Ring Color: Yellow
- Recommended speed: 300 rpm
- Recommended torque: 2.0 N•cm
- KP-E1-25
- Diameter: 0,18 mm
- Taper (%): 02vt
- Cross section: Convex-sided triangle
- Colour of the stem: Violet
- Colour of the ring: Violet
- Recommended speed: 300 rpm
- Recommended torque: 2.0 N•cm
- KP-E2-25
- Diameter: 0.20 mm
- Taper (%): 04vt
- Cross section: Convex-sided triangle
- Stem Color: White
- Ring Color: White
- Recommended speed: 300 rpm
- Recommended torque: 2.0 N•cm
- KP-E3-25
- Diameter: 0.20 mm
- Taper (%): 07vt
- Cross section: Convex-sided triangle
- Stem Color: Yellow
- Ring Color: Yellow
- Recommended speed: 300 rpm
- Recommended torque: 2.0 N•cm
- KP-E4-25
- Diameter: 0.25 mm
- Taper (%): 08vt
- Cross section: Triangle
- Shank Color: Red
- Ring Color: Red
- Recommended speed: 300 rpm
- Recommended torque: 2.0 N•cm
- KP-E5-25
- Diameter: 0.30 mm
- Taper(%): 09vt
- Cross section: Triangle
- Colour of the stem: Blue
- Colour of the ring: Blue
- Recommended speed: 300 rpm
- Recommended torque: 2.0 N•cm
Procedure:


- Explore the canal using K #10 and #15 files.
- Use the file KP-E0-19 (28-DMITE019) to remove the triangular dentin projection in the cervical area, widening the orifice of the canal and creating a access in a straight line.
- Using a K file #15 or larger, determine the working length and confirm the permeability.
- Using the KP-E1-25 (28-DMITE125) file, move the instrument in a slow pecking and brushing motion to establish a glide path to the working length.
- (5.-8.) Using files KP-E2-25 (28-DMITE225) through KP-E5-25 (28-DMITE525), move the instrument in a slow pecking and brushing motion until the final shape of the duct is achieved at the working length.